{"id":25313,"date":"2017-12-14T00:00:00","date_gmt":"2017-12-14T00:00:00","guid":{"rendered":"https:\/\/reznor.co.uk\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/"},"modified":"2023-10-17T15:59:29","modified_gmt":"2023-10-17T15:59:29","slug":"cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor","status":"publish","type":"post","link":"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/","title":{"rendered":"CPD Training Module &#8211; ErP Legislation and Commercial Heating Systems by Reznor"},"content":{"rendered":"<p>Paying for energy is a major cost of running a sports hall \u2013 higher than many other sectors. This CPD, sponsored by Reznor, outlines energy-efficient ways to heat and ventilate sports halls that conform to recent changes in legislation.<\/p><div class='centerme'><iframe loading=\"lazy\" width=\"800\" height=\"480\" src=\"https:\/\/www.youtube.com\/embed\/Qd4n1WfjfZo\" title=\"&#39;Sports Hall Heating and Ventilation&#39; | Reznor - CPD Training Module\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen><\/iframe><\/div><h2 class=\"wp-block-heading\">Introduction<\/h2><p>For specialists in supplying heating, ventilation and air-conditioning systems, sports hall facilities are generally divided into two types: single-use venues, which host sports activities suitable for indoors, such as tennis, badminton and basketball; and those that double-up to cater for a school\u2019s sports activities during the day and host sporting programmes and events for the local community on weekday evenings and during the day at weekends.<\/p><p>The increased use of such multi-purpose halls, with their longer opening hours, means the design of a heating and ventilation system is critical in order to create the best environment for users and, crucially, to keep energy costs to a minimum. Figures from the Carbon Trust suggest that for a typical-sized sports centre, energy accounts for 30% of a venue\u2019s running costs, second only to labour, and higher than most other sectors.<\/p><p>The most effective solution for any given sports hall will ultimately depend on the sort of activities it hosts and the length of time it is used. There are other factors that need to be taken into consideration, such as air movement, ventilation and air quality, maintenance \u2013 and an issue that is deemed highly sensitive in both single and multi-use venues \u2013 noise.<\/p><figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/000_0010.jpg\"><img decoding=\"async\" data-id=\"25383\" src=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/000_0010-1024x637.jpg\" alt=\"\" class=\"wp-image-25383\"\/><\/a><\/figure>\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/000_0056.jpg\"><img decoding=\"async\" data-id=\"25385\" src=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/000_0056-1024x683.jpg\" alt=\"\" class=\"wp-image-25385\"\/><\/a><\/figure>\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/000_0059.jpg\"><img decoding=\"async\" data-id=\"25386\" src=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/000_0059-1024x597.jpg\" alt=\"\" class=\"wp-image-25386\"\/><\/a><\/figure><\/figure><h2 class=\"wp-block-heading\">Flue Point Issues<\/h2><p>With air movement being a key design consideration for many single-use venues, heating by infrared radiation has been the established choice for a number of years. Radiant tubes provide blanket heat coverage without moving the air, and being mounted overhead they produce infrared heat that is directed downwards towards a hall\u2019s occupants via a reflector. Contemporary radiant tube heaters feature combustion that takes place within the firing tube, reducing both the size and weight of the unit required, as well as lowering noise levels. The burner heads of such units create a better flame configuration, improving temperature distribution, creating more even heat coverage and the need for fewer units. The use of high-efficiency burners enables fuel savings of up to 75% compared with conventional heating systems.<\/p><p>Large buildings heated with unitary radiant tubes often require multiple flue penetrations, either in the roof or through a wall, to remove exhaust gases. But multiple flue points can subsequently compromise the integrity of the building fabric and increase installation costs.<\/p><p>The use of a combined common flue system for unitary radiant tube heaters reduces the number of penetrations throughout the fabric of a building, and such flues are quieter due to there being fewer flue fans in operation.<\/p><p>Hot gas vacuum fans can be mounted inside or outside the building, increasing practical and aesthetic options for both the installer and the site\u2019s operators.<\/p><p>On the issue of noise, Building Bulletin 93 \u2013 Acoustic Design of Schools: Performance Standards \u2013 was updated in February 2015 and&nbsp;sets out what the government calls \u201cminimum performance standards for the acoustics of school buildings, and describes the normal means of demonstrating compliance with the Building Regulations\u201d. These, or other requirements such as Sport England\u2019s Affordable Sports Hall Guidance, stipulate the need for a continuous multi-burner radiant tube system, given that the legislation states that noise should not exceed 50 decibels for a swimming pool and 40 decibels for an indoor sports hall.<\/p><p>A single external burner can be used with a radiant strip heating system to produce a \u201cblanket coverage\u201d radiant environment via a low surface temperature emitter without moving or disturbing the air, which benefits the internal environment, and using fuels such as natural gas, propane or diesel. The burner \u2013 power for which ranges from 50kW to 400kW \u2013 for each system is designed to be fitted outside the building or area to be heated, making maintenance easier and lowering noise levels within the facility.<\/p><figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-2 is-layout-flex wp-block-gallery-is-layout-flex\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/Worcester_Warriors_Slider_2.jpg\"><img decoding=\"async\" data-id=\"25387\" src=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/Worcester_Warriors_Slider_2.jpg\" alt=\"\" class=\"wp-image-25387\"\/><\/a><\/figure>\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/Worcester_Warriors_Slider_3.jpg\"><img decoding=\"async\" data-id=\"25388\" src=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/Worcester_Warriors_Slider_3.jpg\" alt=\"\" class=\"wp-image-25388\"\/><\/a><\/figure>\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/Worcester_Warriors_Slider_4.jpg\"><img decoding=\"async\" data-id=\"25389\" src=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/Worcester_Warriors_Slider_4.jpg\" alt=\"\" class=\"wp-image-25389\"\/><\/a><\/figure>\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/Worcester_Warriors_Slider_5.jpg\"><img decoding=\"async\" data-id=\"25390\" src=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/Worcester_Warriors_Slider_5.jpg\" alt=\"\" class=\"wp-image-25390\"\/><\/a><\/figure>\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/Worcester_Warriors_Slider_6.jpg\"><img decoding=\"async\" data-id=\"25391\" src=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/Worcester_Warriors_Slider_6.jpg\" alt=\"\" class=\"wp-image-25391\"\/><\/a><\/figure><\/figure><h2 class=\"wp-block-heading\">Warm Air Systems<\/h2><p>The use of multi-use sports halls, combining school and community use, has been a growing trend in recent years, and the inevitable longer operating hours mean the type of heating system has be precisely tailored to the facility. A warm air system can be used to provide heating and ventilation,&nbsp;with heater batteries featuring low-pressure hot water systems, direct or indirectly fired gas, heat pumps or steam. When used for sports during&nbsp;winter at low occupancy levels, there is a demand for heat that can be controlled by keeping the internal temperatures relatively low.<\/p><p>During times of high occupancy, for example during spring and summer exam periods, heating requirements are very different \u2013 excess heat must be removed from the hall to prevent overheating, while there should be sufficient ventilation for occupants. Overheating, rather than keeping&nbsp;warm, is often more of an issue for sports halls, particularly multi-use ones, and more difficult to resolve effectively.<\/p><p>Maintaining high volumes of air flow will help keep indoor temperatures during the summer months at optimum levels.<\/p><p>A common solution to control summer temperatures is to use roof-mounted ventilation units with integral extract fans. But this option has its limitations, especially when the external air temperature drops during the autumn and winter months, when this solution becomes effectively unusable.<\/p><p>A better idea, especially where occupants undertake vigorous exercise, is to provide a&nbsp;single combined heating, cooling and ventilation system. This combined option means cooling during warmer months can be provided by operating the fan and outside air simply to&nbsp;offset increases in internal heat. This could come in the form of an Air Handling Unit (AHU) or a Packaged Rooftop Unit, which come with a wide range of heat outputs, air volumes and external static pressures.<\/p><p>For an AHU, gas-fired appliances are usually acknowledged as the best heat sources, since they can work independently of the heating systems that supply the rest of the property during school hours. By using an indirect fired gas burner, thermal efficiencies in excess of 91% (net calorific value) can be achieved; by using condensing burners the increased efficiencies make them eligible for Enhanced Capital Allowances.<\/p><p>For the Packaged Rooftop Unit, a reverse&nbsp;cycle DX coil can use heat pump technology&nbsp;when gas is not present; or when electric is the preferred energy source, when solar photovoltaic panels are present. For both options, installation time can be reduced by supplying the units to site preassembled and fully wired complete with all motor starters. Locating equipment externally means no internal disruption during maintenance, and avoiding costly shutdowns.<\/p><p>Warm air systems can use a variety of ductwork applications including conventional, jet nozzle and induction air distribution systems. A fabric material system uses a lightweight fabric duct that has many small outlet nozzles, which are evenly spaced along the length of the duct, or alternatively are located in specific areas.<\/p><p>Air is introduced into the duct and forced&nbsp;through the nozzles at high speed, creating a negative pressure zone. This induces surrounding air and recirculates heat from lighting and&nbsp;heat that has risen to the roof space and so&nbsp;would otherwise be wasted. In sports halls,&nbsp;this can provide energy savings of around&nbsp;15%, as traditional destratification\/air&nbsp;recirculation fans cannot be used because of the air movement created.<\/p><p>The result is evenly distributed heat at low air velocities, with low noise levels that eliminates excess heat stratification and the need for air recirculation fans. With most sports halls needing both heating and ventilation, AHUs can be a better option than a radiant system since&nbsp;they can meet both requirements through&nbsp;a single installation.<\/p><figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-3 is-layout-flex wp-block-gallery-is-layout-flex\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/000_0075.jpg\"><img decoding=\"async\" data-id=\"25393\" src=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/000_0075-1024x683.jpg\" alt=\"\" class=\"wp-image-25393\"\/><\/a><\/figure>\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/000_0099.jpg\"><img decoding=\"async\" data-id=\"25392\" src=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/000_0099-1024x683.jpg\" alt=\"\" class=\"wp-image-25392\"\/><\/a><\/figure>\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/Welsh-National-Velodrome.jpg\"><img decoding=\"async\" data-id=\"25378\" src=\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2023\/10\/Welsh-National-Velodrome.jpg\" alt=\"\" class=\"wp-image-25378\"\/><\/a><\/figure><\/figure><h2 class=\"wp-block-heading\">Legislative Considerations<\/h2><p>There have been recent changes to legislation covering energy-related products (ErP) in order to increase their efficiency. ErP Lot 20 came into force at the beginning of 2018. It covers gas-fired radiant heating and specifies that such units must have a seasonal efficiency of 74% or above, as well as a maximum nitrogen oxide (NOx) emission of 200mg per kWh.<\/p><p>The UK\u2019s looming departure from the European Union will not affect the need for UK systems to meet these requirements. The new regulations will also require that manufacturers of heaters publish the seasonal efficiency of their products in maintenance manuals and online.<\/p><p>Lot 21, covering warm air heaters has a two stage introduction \u2013 1st January 2018 sees a minimum seasonal efficiency of 72%, whilst in September a maximum NOx emission of 100mg\/kWh comes into force.<\/p><p>Lot 6, which began on 1 January 2016,&nbsp;requires ventilation units to also meet minimum efficiency standards, helping to reduce life-cycle costs and improve sustainability. It covers bidirectional ventilation units, which feature two opposing air streams, and unidirectional ventilation units, which have only one airstream. Both are covered by a set of minimum requirements including variable speed systems, thermal bypasses fitted to heat recovery systems with minimum efficiency of 73%, and limits on internal specific fan power.<\/p><h2 class=\"wp-block-heading\">How to take this module<\/h2><p>UBM\u2019s CPD distance-learning programme is open to anyone seeking to develop their knowledge and skills. Each module also offers members of professional institutions an opportunity to earn between 30 and 90 minutes of credits towards their annual CPD requirement.<\/p><p>This article is accredited by the CPD Certification Service. To earn CPD credits, read the article and then click the link below to complete your details and answer the questions. You will receive your results instantly, and if all the questions are correctly answered, you will be able to download your CPD certificate straight away.<\/p><p>DEADLINE: 13 APRIL 2018<\/p><p><\/p><p><a class=\"carmineredbutton\" href=\"http:\/\/cpd.building.co.uk\/survey.aspx?survey=1393&amp;_ga=2.202829969.1250438665.1521106441-1576438564.1521106440\">Click here to begin the module<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Paying for energy is a major cost of running a sports hall \u2013 higher than many other sectors. This CPD, sponsored by Reznor, outlines energy-efficient ways to heat and ventilate [&hellip;]<\/p>\n","protected":false},"author":2740,"featured_media":26208,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2403],"tags":[],"class_list":["post-25313","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>CPD Training Module - ErP Legislation and Commercial Heating Systems by Reznor - Gaz Industrie<\/title>\n<meta name=\"robots\" content=\"noindex, follow\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"CPD Training Module - ErP Legislation and Commercial Heating Systems by Reznor - Gaz Industrie\" \/>\n<meta property=\"og:description\" content=\"Paying for energy is a major cost of running a sports hall \u2013 higher than many other sectors. This CPD, sponsored by Reznor, outlines energy-efficient ways to heat and ventilate [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/\" \/>\n<meta property=\"og:site_name\" content=\"Gaz Industrie\" \/>\n<meta property=\"article:published_time\" content=\"2017-12-14T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-10-17T15:59:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2017\/12\/Welsh-National-Velodrome.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"627\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Christelle Soupin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Christelle Soupin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"10 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/\"},\"author\":{\"name\":\"Christelle Soupin\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/person\/8123794105d2dc89fb00b5490f60a7d2\"},\"headline\":\"CPD Training Module &#8211; ErP Legislation and Commercial Heating Systems by Reznor\",\"datePublished\":\"2017-12-14T00:00:00+00:00\",\"dateModified\":\"2023-10-17T15:59:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/\"},\"wordCount\":1590,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2017\/12\/Welsh-National-Velodrome.jpg\",\"articleSection\":[\"News\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/\",\"url\":\"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/\",\"name\":\"CPD Training Module - ErP Legislation and Commercial Heating Systems by Reznor - Gaz Industrie\",\"isPartOf\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2017\/12\/Welsh-National-Velodrome.jpg\",\"datePublished\":\"2017-12-14T00:00:00+00:00\",\"dateModified\":\"2023-10-17T15:59:29+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/#primaryimage\",\"url\":\"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2017\/12\/Welsh-National-Velodrome.jpg\",\"contentUrl\":\"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2017\/12\/Welsh-National-Velodrome.jpg\",\"width\":1000,\"height\":627},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.gazindustrie.fr\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"CPD Training Module &#8211; ErP Legislation and Commercial Heating Systems by Reznor\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#website\",\"url\":\"https:\/\/www.gazindustrie.fr\/en\/\",\"name\":\"Gaz Industrie\",\"description\":\"Une exp\u00e9rience sans \u00e9gale\",\"publisher\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gazindustrie.fr\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#organization\",\"name\":\"Empress HVAC\",\"url\":\"https:\/\/www.gazindustrie.fr\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2019\/12\/empress_logo_email.png\",\"contentUrl\":\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2019\/12\/empress_logo_email.png\",\"width\":238,\"height\":109,\"caption\":\"Empress HVAC\"},\"image\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/person\/8123794105d2dc89fb00b5490f60a7d2\",\"name\":\"Christelle Soupin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/fc0aa72968a2442fa31cc02354960371?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/fc0aa72968a2442fa31cc02354960371?s=96&d=mm&r=g\",\"caption\":\"Christelle Soupin\"},\"url\":\"https:\/\/www.gazindustrie.fr\/en\/author\/christelle-soupin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"CPD Training Module - ErP Legislation and Commercial Heating Systems by Reznor - Gaz Industrie","robots":{"index":"noindex","follow":"follow"},"og_locale":"en_US","og_type":"article","og_title":"CPD Training Module - ErP Legislation and Commercial Heating Systems by Reznor - Gaz Industrie","og_description":"Paying for energy is a major cost of running a sports hall \u2013 higher than many other sectors. This CPD, sponsored by Reznor, outlines energy-efficient ways to heat and ventilate [&hellip;]","og_url":"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/","og_site_name":"Gaz Industrie","article_published_time":"2017-12-14T00:00:00+00:00","article_modified_time":"2023-10-17T15:59:29+00:00","og_image":[{"width":1000,"height":627,"url":"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2017\/12\/Welsh-National-Velodrome.jpg","type":"image\/jpeg"}],"author":"Christelle Soupin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Christelle Soupin","Est. reading time":"10 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/#article","isPartOf":{"@id":"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/"},"author":{"name":"Christelle Soupin","@id":"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/person\/8123794105d2dc89fb00b5490f60a7d2"},"headline":"CPD Training Module &#8211; ErP Legislation and Commercial Heating Systems by Reznor","datePublished":"2017-12-14T00:00:00+00:00","dateModified":"2023-10-17T15:59:29+00:00","mainEntityOfPage":{"@id":"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/"},"wordCount":1590,"commentCount":0,"publisher":{"@id":"https:\/\/www.gazindustrie.fr\/en\/#organization"},"image":{"@id":"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2017\/12\/Welsh-National-Velodrome.jpg","articleSection":["News"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/","url":"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/","name":"CPD Training Module - ErP Legislation and Commercial Heating Systems by Reznor - Gaz Industrie","isPartOf":{"@id":"https:\/\/www.gazindustrie.fr\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/#primaryimage"},"image":{"@id":"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2017\/12\/Welsh-National-Velodrome.jpg","datePublished":"2017-12-14T00:00:00+00:00","dateModified":"2023-10-17T15:59:29+00:00","breadcrumb":{"@id":"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/#primaryimage","url":"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2017\/12\/Welsh-National-Velodrome.jpg","contentUrl":"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2017\/12\/Welsh-National-Velodrome.jpg","width":1000,"height":627},{"@type":"BreadcrumbList","@id":"https:\/\/www.gazindustrie.fr\/en\/cpd-training-module-erp-legislation-and-commercial-heating-systems-by-reznor\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.gazindustrie.fr\/en\/"},{"@type":"ListItem","position":2,"name":"CPD Training Module &#8211; ErP Legislation and Commercial Heating Systems by Reznor"}]},{"@type":"WebSite","@id":"https:\/\/www.gazindustrie.fr\/en\/#website","url":"https:\/\/www.gazindustrie.fr\/en\/","name":"Gaz Industrie","description":"Une exp\u00e9rience sans \u00e9gale","publisher":{"@id":"https:\/\/www.gazindustrie.fr\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gazindustrie.fr\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.gazindustrie.fr\/en\/#organization","name":"Empress HVAC","url":"https:\/\/www.gazindustrie.fr\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/logo\/image\/","url":"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2019\/12\/empress_logo_email.png","contentUrl":"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2019\/12\/empress_logo_email.png","width":238,"height":109,"caption":"Empress HVAC"},"image":{"@id":"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/person\/8123794105d2dc89fb00b5490f60a7d2","name":"Christelle Soupin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/fc0aa72968a2442fa31cc02354960371?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/fc0aa72968a2442fa31cc02354960371?s=96&d=mm&r=g","caption":"Christelle Soupin"},"url":"https:\/\/www.gazindustrie.fr\/en\/author\/christelle-soupin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/posts\/25313"}],"collection":[{"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/users\/2740"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/comments?post=25313"}],"version-history":[{"count":0,"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/posts\/25313\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/media\/26208"}],"wp:attachment":[{"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/media?parent=25313"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/categories?post=25313"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/tags?post=25313"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}