{"id":30309,"date":"2023-11-23T14:52:15","date_gmt":"2023-11-23T14:52:15","guid":{"rendered":"https:\/\/www.reznor.co.uk\/?p=30309"},"modified":"2023-11-23T14:52:20","modified_gmt":"2023-11-23T14:52:20","slug":"top-tips-on-how-to-install-a-gas-fired-warm-air-heater","status":"publish","type":"post","link":"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/","title":{"rendered":"Top Tips on How to Install a Gas-fired Warm Air Heater"},"content":{"rendered":"<p class=\"p1\">Installing a Reznor gas-fired warm air heater is a cost-effective and efficient choice for your large industrial or commercial space.\nOur heaters are known for their efficiency and durability, but a successful installation is crucial to ensure they function optimally. In particular, our PHOTON is our latest generation suspended gas fired\u202funit\u202fheater designed to deliver outstanding energy efficiency, performance and economy for reduced operating and life cycle costs.<\/p>\n<p class=\"p1\">With the heating season approaching, this guide will provide you with the top tips on how to install the Photon warm air heater safely and effectively, ensuring you are prepared for the colder months.<\/p>\n<h2 class=\"p1\"><b>Step 1: Gather Your Tools and Materials needed for safe installation<\/b><\/h2>\n<p class=\"p1\">Being well-prepared when installing gas-fired warm air unit heaters in a large industrial space is of paramount importance. It serves as a critical safeguard against potential risks and ensures the smooth functioning of the heating system. Adequate preparation involves a thorough understanding of all relevant standards, codes of practice, and local regulations, ensuring that the installation complies with safety requirements.<\/p>\n<p class=\"p1\">Additionally, precise positioning and location are vital to prevent hazardous situations, especially in industrial environments prone to flammable substances. Proper planning also extends to the ventilation and flueing of combustion byproducts to maintain air quality. Electrical considerations must not be overlooked, and having a qualified electrician on hand guarantees that the installation aligns with industry regulations. Lastly, a well-prepared approach to gas pipework, with the inclusion of isolating valves and flexible connections, ensures safety and convenience during maintenance. In essence, preparedness is the cornerstone of a successful and secure unit heater installation, safeguarding both the facility and its occupants.<\/p>\n<h2 class=\"p1\">Make the most of our installation kits for the Photon range<\/h2>\n<p class=\"p3\">At Reznor it\u2019s vital to us to provide our customers with all the tools required for efficient productivity. As a HVAC engineer, we know how busy the heating season can get, with many customers leaving their servicing or installation to the last minute, or simply forgetting. That\u2019s why we\u2019ve created our easy installation kits, so you are equipped for the job.<\/p>\n<p class=\"p3\">Our Photon installation kit includes:<\/p>\n\n<table class=\"t1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td class=\"td1\" valign=\"top\">\n<p class=\"p3\">IK-WA-V-A<\/p>\n<\/td>\n<td class=\"td2\" valign=\"top\">\n<p class=\"p3\">Vertical Concentric termination Installation Kit for Photon10 &amp; 20 and ULSA025 &amp; 035<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"td3\" valign=\"top\">\n<p class=\"p3\">IK-WA-V-C<\/p>\n<\/td>\n<td class=\"td4\" valign=\"top\">\n<p class=\"p3\">Vertical Concentric termination Installation Kit for Photon25<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"td1\" valign=\"top\">\n<p class=\"p3\">IK-WA-V-D<\/p>\n<\/td>\n<td class=\"td2\" valign=\"top\">\n<p class=\"p3\">Vertical Concentric termination Installation Kit for Photon35, 45 &amp; 55 and ULSA075 &amp; 100<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"td3\" valign=\"top\">\n<p class=\"p3\">IK-WA-V-E<\/p>\n<\/td>\n<td class=\"td4\" valign=\"top\">\n<p class=\"p3\">Vertical Concentric termination Installation Kit for Photon65, 70, 100<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"td5\" valign=\"top\">\n<p class=\"p3\">IK-WA-V-F<\/p>\n<\/td>\n<td class=\"td6\" valign=\"top\">\n<p class=\"p3\">Vertical Concentric termination Installation Kit for Photon120<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"td1\" valign=\"top\">\n<p class=\"p3\">IK-WA-H-A<\/p>\n<\/td>\n<td class=\"td2\" valign=\"top\">\n<p class=\"p3\">Horizontal Concentric termination Installation Kit for Photon10 &amp; 20 and ULSA025 &amp; 035<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"td3\" valign=\"top\">\n<p class=\"p3\">IK-WA-H-C<\/p>\n<\/td>\n<td class=\"td4\" valign=\"top\">\n<p class=\"p3\">Horizontal Concentric termination Installation Kit for Photon25<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"td1\" valign=\"top\">\n<p class=\"p3\">IK-WA-H-D<\/p>\n<\/td>\n<td class=\"td2\" valign=\"top\">\n<p class=\"p3\">Horizontal Concentric termination Installation Kit for Photon35, 45 &amp; 55 and ULSA075 &amp; 100<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"td1\" valign=\"top\">\n<p class=\"p3\">IK-WA-H-E<\/p>\n<\/td>\n<td class=\"td2\" valign=\"top\">\n<p class=\"p3\">Horizontal Concentric termination Installation Kit for Photon65, 70, 100<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"td3\" valign=\"top\">\n<p class=\"p3\">IK-WA-H-F<\/p>\n<\/td>\n<td class=\"td4\" valign=\"top\">\n<p class=\"p3\">Horizontal Concentric termination Installation Kit for Photon120<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n&nbsp;\n\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-5563 size-large\" src=\"https:\/\/reznor.eu\/wp-content\/uploads\/2023\/10\/Screenshot-2023-10-04-at-14.05.47-1024x571.png\" alt=\"Install the Photon Warm Air Heater\" width=\"1024\" height=\"571\" \/><br\/><br\/>\n<h2 class=\"p1\">Installation tips for the Photon warm air heater<\/h2>\n<p class=\"p1\"><b>Installation &#8211;<\/b> Firstly, ensure that the units are not only properly installed but also fully aligned with all the pertinent standards and codes of practice. Additionally, adhere to the guidelines set by local authorities, fire officers, insurers, and the installation manual&#8217;s provided details.<\/p>\n<p class=\"p1\"><b>Position and Location &#8211;<\/b> Each heater is equipped with four built-in suspension points featuring an M10 female thread. It&#8217;s imperative to avoid installing the units in environments containing flammable or explosive vapours, combustible dust, halogenated hydrocarbons, chlorinated vapours, or areas where contaminants could negatively impact electrical motors and connections.<\/p>\n<p class=\"p1\"><b>Flueing &#8211;<\/b> The combustion byproducts from the unit must be vented outside the building. These units have a blown burner and can be installed in room-sealed or flue-only applications classified as B23, B53, C13, and C33 under the PD CR 1749 &#8220;Classification of gas appliances according to the method of supplying combustion air and evacuation of combustion products (types).&#8221; Adequate consideration should be given to providing air for combustion and ventilation.<\/p>\n<p class=\"p1\"><b>Electrical &#8211;<\/b> These units are suitable for a single-phase electrical supply and should be installed by a qualified electrician to meet the current IET Regulations. The electrical supply should remain connected unless isolated for maintenance purposes.<\/p>\n<p class=\"p1\"><b>Gas Pipework &#8211;<\/b> Each heater should be equipped with a flexible connection, isolating valves, and unions. The gas pipework must be installed in accordance with the applicable standards and codes of practice.<\/p>\n<div style='display:flex; flex-direction: column; text-align:center; width:100%; align-items: center; gap: 20px;'>\n<img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5562 size-full\" src=\"https:\/\/reznor.eu\/wp-content\/uploads\/2023\/10\/IK-WA-V-E-450x450-1.jpg\" alt=\"Vertical Concentric termination Installation Kit for Photon65, 70, 100\" width=\"450\" height=\"450\" \/>\n<span class='blog-caption'>Vertical Concentric termination Installation Kit for Photon65, 70, 100<\/span>\n\n<p>Get Started below and check out our range of installation kits for the Photon Range<br\/><br\/><a href='\/product-category\/spares\/flue-and-accessories\/installation-kits\/' style='text-decoration: none;' class='carmineredbutton'>Purchase here<\/a><\/p>\n<\/div>\n<h2 class=\"p1\">Be prepared for the heating season<\/h2>\n<p class=\"p1\">Being as prepared as possible is key in the lead up to the heating season; we\u2019re proud to support HVAC engineers and contractors with our products and services to enable job satisfaction and productivity.<\/p>\n<p class=\"p1\">Reznor is the UK&#8217;s trusted supplier of sustainable HVAC solutions &#8211; delivering efficiency and cost savings when it matters most. We manufacture a wide range of reliable industrial and commercial HVAC solutions, with over 130 years of experience. If you\u2019re looking for extra tips, installation and product guides, please visit our <a href=\"https:\/\/literature.reznor.eu\/\"><span class=\"s1\">extensive literature library<\/span><\/a> and download for free.<\/p>\n<p class=\"p1\"><span class=\"s1\"><a href=\"\/contact-us\/\">Get in touch today<\/a><\/span> or <a href=\"https:\/\/linktr.ee\/reznoruk\"><span class=\"s1\">follow us on social media<\/span><\/a>; you can also view our brand new <a href=\"https:\/\/www.youtube.com\/@nortekhvac\/featured\"><span class=\"s1\">YouTube channel<\/span><\/a> to see what we get up to at the Reznor UK HQ!<\/p>","protected":false},"excerpt":{"rendered":"<p>Installing a Reznor gas-fired warm air heater is a cost-effective and efficient choice for your large industrial or commercial space. Our heaters are known for their efficiency and durability, but [&hellip;]<\/p>\n","protected":false},"author":2253,"featured_media":30310,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2403],"tags":[],"class_list":["post-30309","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Top Tips on How to Install a Gas-fired Warm Air Heater - Gaz Industrie<\/title>\n<meta name=\"robots\" content=\"noindex, follow\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Top Tips on How to Install a Gas-fired Warm Air Heater - Gaz Industrie\" \/>\n<meta property=\"og:description\" content=\"Installing a Reznor gas-fired warm air heater is a cost-effective and efficient choice for your large industrial or commercial space. Our heaters are known for their efficiency and durability, but [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/\" \/>\n<meta property=\"og:site_name\" content=\"Gaz Industrie\" \/>\n<meta property=\"article:published_time\" content=\"2023-11-23T14:52:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-11-23T14:52:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2023\/11\/Screenshot-2023-10-04-at-14.05.47.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1760\" \/>\n\t<meta property=\"og:image:height\" content=\"982\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Kieran Penrice\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Kieran Penrice\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/\"},\"author\":{\"name\":\"Kieran Penrice\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/person\/68727e2086e231fba3ab9f419b259539\"},\"headline\":\"Top Tips on How to Install a Gas-fired Warm Air Heater\",\"datePublished\":\"2023-11-23T14:52:15+00:00\",\"dateModified\":\"2023-11-23T14:52:20+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/\"},\"wordCount\":855,\"publisher\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2023\/11\/Screenshot-2023-10-04-at-14.05.47.png\",\"articleSection\":[\"News\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/\",\"url\":\"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/\",\"name\":\"Top Tips on How to Install a Gas-fired Warm Air Heater - Gaz Industrie\",\"isPartOf\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2023\/11\/Screenshot-2023-10-04-at-14.05.47.png\",\"datePublished\":\"2023-11-23T14:52:15+00:00\",\"dateModified\":\"2023-11-23T14:52:20+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/#primaryimage\",\"url\":\"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2023\/11\/Screenshot-2023-10-04-at-14.05.47.png\",\"contentUrl\":\"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2023\/11\/Screenshot-2023-10-04-at-14.05.47.png\",\"width\":1760,\"height\":982},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.gazindustrie.fr\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Top Tips on How to Install a Gas-fired Warm Air Heater\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#website\",\"url\":\"https:\/\/www.gazindustrie.fr\/en\/\",\"name\":\"Gaz Industrie\",\"description\":\"Une exp\u00e9rience sans \u00e9gale\",\"publisher\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gazindustrie.fr\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#organization\",\"name\":\"Empress HVAC\",\"url\":\"https:\/\/www.gazindustrie.fr\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2019\/12\/empress_logo_email.png\",\"contentUrl\":\"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2019\/12\/empress_logo_email.png\",\"width\":238,\"height\":109,\"caption\":\"Empress HVAC\"},\"image\":{\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/person\/68727e2086e231fba3ab9f419b259539\",\"name\":\"Kieran Penrice\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/06d63f144ce8fe56f1e8910df5f03908?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/06d63f144ce8fe56f1e8910df5f03908?s=96&d=mm&r=g\",\"caption\":\"Kieran Penrice\"},\"url\":\"https:\/\/www.gazindustrie.fr\/en\/author\/kieran-penrice\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Top Tips on How to Install a Gas-fired Warm Air Heater - Gaz Industrie","robots":{"index":"noindex","follow":"follow"},"og_locale":"en_US","og_type":"article","og_title":"Top Tips on How to Install a Gas-fired Warm Air Heater - Gaz Industrie","og_description":"Installing a Reznor gas-fired warm air heater is a cost-effective and efficient choice for your large industrial or commercial space. Our heaters are known for their efficiency and durability, but [&hellip;]","og_url":"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/","og_site_name":"Gaz Industrie","article_published_time":"2023-11-23T14:52:15+00:00","article_modified_time":"2023-11-23T14:52:20+00:00","og_image":[{"width":1760,"height":982,"url":"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2023\/11\/Screenshot-2023-10-04-at-14.05.47.png","type":"image\/png"}],"author":"Kieran Penrice","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Kieran Penrice","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/#article","isPartOf":{"@id":"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/"},"author":{"name":"Kieran Penrice","@id":"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/person\/68727e2086e231fba3ab9f419b259539"},"headline":"Top Tips on How to Install a Gas-fired Warm Air Heater","datePublished":"2023-11-23T14:52:15+00:00","dateModified":"2023-11-23T14:52:20+00:00","mainEntityOfPage":{"@id":"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/"},"wordCount":855,"publisher":{"@id":"https:\/\/www.gazindustrie.fr\/en\/#organization"},"image":{"@id":"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2023\/11\/Screenshot-2023-10-04-at-14.05.47.png","articleSection":["News"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/","url":"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/","name":"Top Tips on How to Install a Gas-fired Warm Air Heater - Gaz Industrie","isPartOf":{"@id":"https:\/\/www.gazindustrie.fr\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/#primaryimage"},"image":{"@id":"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2023\/11\/Screenshot-2023-10-04-at-14.05.47.png","datePublished":"2023-11-23T14:52:15+00:00","dateModified":"2023-11-23T14:52:20+00:00","breadcrumb":{"@id":"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/#primaryimage","url":"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2023\/11\/Screenshot-2023-10-04-at-14.05.47.png","contentUrl":"https:\/\/www.gazindustrie.fr\/wp-content\/uploads\/2023\/11\/Screenshot-2023-10-04-at-14.05.47.png","width":1760,"height":982},{"@type":"BreadcrumbList","@id":"https:\/\/www.gazindustrie.fr\/en\/top-tips-on-how-to-install-a-gas-fired-warm-air-heater\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.gazindustrie.fr\/en\/"},{"@type":"ListItem","position":2,"name":"Top Tips on How to Install a Gas-fired Warm Air Heater"}]},{"@type":"WebSite","@id":"https:\/\/www.gazindustrie.fr\/en\/#website","url":"https:\/\/www.gazindustrie.fr\/en\/","name":"Gaz Industrie","description":"Une exp\u00e9rience sans \u00e9gale","publisher":{"@id":"https:\/\/www.gazindustrie.fr\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gazindustrie.fr\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.gazindustrie.fr\/en\/#organization","name":"Empress HVAC","url":"https:\/\/www.gazindustrie.fr\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/logo\/image\/","url":"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2019\/12\/empress_logo_email.png","contentUrl":"https:\/\/dev.nortekhvac.eu\/wp-content\/uploads\/2019\/12\/empress_logo_email.png","width":238,"height":109,"caption":"Empress HVAC"},"image":{"@id":"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/person\/68727e2086e231fba3ab9f419b259539","name":"Kieran Penrice","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.gazindustrie.fr\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/06d63f144ce8fe56f1e8910df5f03908?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/06d63f144ce8fe56f1e8910df5f03908?s=96&d=mm&r=g","caption":"Kieran Penrice"},"url":"https:\/\/www.gazindustrie.fr\/en\/author\/kieran-penrice\/"}]}},"_links":{"self":[{"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/posts\/30309"}],"collection":[{"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/users\/2253"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/comments?post=30309"}],"version-history":[{"count":0,"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/posts\/30309\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/media\/30310"}],"wp:attachment":[{"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/media?parent=30309"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/categories?post=30309"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gazindustrie.fr\/en\/wp-json\/wp\/v2\/tags?post=30309"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}